Indian Journal of Cancer
Home  ICS  Feedback Subscribe Top cited articles Login 
Users Online :343
Small font sizeDefault font sizeIncrease font size
Navigate Here
 »   Next article
 »   Previous article
 »   Table of Contents

Resource Links
 »   Similar in PUBMED
 »  Search Pubmed for
 »  Search in Google Scholar for
 »Related articles
 »   Citation Manager
 »   Access Statistics
 »   Reader Comments
 »   Email Alert *
 »   Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed273    
    Printed20    
    Emailed0    
    PDF Downloaded57    
    Comments [Add]    

Recommend this journal

 

 ORIGINAL ARTICLE
Year : 2018  |  Volume : 55  |  Issue : 3  |  Page : 226-229

Effectiveness of abdominal compression in reducing internal target motion during conformal radiotherapy for carcinoma stomach – A pilot study


Department of Radiation Oncology, Amala Institute of Medical Sciences, Thrissur, Kerala, India

Correspondence Address:
Dr. Jomon C Raphael
Department of Radiation Oncology, Amala Institute of Medical Sciences, Thrissur, Kerala
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijc.IJC_95_18

Rights and Permissions

AIM: To assess the effectiveness of abdominal compression in reducing internal target motion during conformal radiotherapy for stomach cancer. MATERIALS AND METHODS: A pilot study was conducted on five patients who received adjuvant radiotherapy for stomach cancer. All the patients had surgical clips and were offered radiotherapy and concurrent chemotherapy as per the institutional protocol. An abdominal compression device was developed consisting of a triangular Styrofoam's plate and an inflatable air bladder that was positioned over the patients' abdomen. The pneumatic pressure was set according to the patients' comfort. On the simulation day, patients had two computed tomography (CT)-scanning sessions, with and without abdominal compression. Target volumes and organs at risk (OAR) were delineated on the CT images without compression. On the treatment day, fluoroscopy was acquired with onboard imager (OBI) and movements of surgical clips with and without compression analyzed with the help of a tracker software. Observed values with and without abdominal compression were compared. RESULTS: Abdominal compression usage has reduced the mean breathing excursion (MBE) in medio lateral(ML) direction from 5.92mm to 4.15 mm and in cranio caudal direction (CC) from 11.3mm to 7.2mm. The range of reduction by 29.85% in the ML and 36.86% in CC direction. The average residual breathing excursion was 1.766 mm (SD = 1.33 mm) in the ML and 4.02 mm (SD = 2.18 mm) in the CC direction, respectively. CONCLUSION: Abdominal compression was useful in reducing internal target motion during stomach cancer conformal radiotherapy. The device we developed is patient friendly and cost-effective.






[FULL TEXT] [PDF]*


        
Print this article     Email this article

  Site Map | What's new | Copyright and Disclaimer
  Online since 1st April '07
  © 2007 - Indian Journal of Cancer | Published by Wolters Kluwer - Medknow